Scope of Work

CAUTION: The following is a reference tool only. Please consult the appropriate fan installation guide for complete installation instructions and safety guidelines.

WARNING: To reduce the risk of electric shock, wiring should be performed by a qualified electrician! Incorrect assembly can cause electric shock or damage the motor and the controller!

WARNING: Fan installation must be in accordance with the National Electrical Code, AS/NZ 3000, and all local codes. Failure to comply with these codes could result in personal injury or property damage.

CAUTION: The Big Ass Fans product warranty will not cover equipment damage or failure that is caused by improper installation of customer-responsible work.

ATTENTION: BIG ASS FANS IS NOT RESPONSIBLE FOR RECEIVING OR HOUSING THE FAN IN A SAFE, DRY PLACE UNTIL INSTALLATION.

General

  • This quote includes regular working hours from 7:00am to 5:00pm Monday-Friday. Afterhours or weekend premium charge will be applied.
  • If installation is scheduled afterhours or on a weekend, then customer must allow installer(s) to perform a site inspection prior to scheduled installation date and time. (at least one work shift prior for afterhours, and at least one day prior for weekend)
  • Any bridge cranes in or near the fan installation area must be locked out during the fan installation.
  • In order to activate the warranty, the Check-In and Close-Out forms must be returned to Big Ass Fans.
  • Whether provided by Big Ass Fans or owner, lift is to be a two-man 7.6m scissor lift, unless otherwise specified.
  • If a lift is to be provided by the owner and that lift is unavailable or deemed to be in an unsafe condition, a replacement lift will be ordered and charged to the owner as well as any down time as a result.
  • Motor/controller is to be supplied as part of the fan package by Big Ass Fans.
  • Roof insulation that is currently in place will not be touched or modified.
  • Angle iron or other steel added by installer in commercial or finished (non-industrial) spaces will be painted to match by installer.
  • The area is to be clean and in operating condition upon completion.
  • Any delays to the installers as a result of the owner/owners representatives including access to the work area(s), delivery of the fans to the installers, or delays related to indecision about fan/controller placement will result in a back bill charge. Trips to the job site where scheduled work cannot be performed will result in a back bill charge to the owner.

Level 1 Scope of Work

Big Ass Fans responsibility consists of:

  • Attach mounting to I-Beam or standard steel Angle Irons
  • Attach extension tube to upper yoke
  • Secure the safety cable
  • Attach lower yoke to extension tube
  • Attach motor frame to lower yoke
  • Attach winglets to airfoils
  • Attach foil retainers and airfoils to hub

(DOES NOT INCLUDE start-up or operational training)

Owner's responsibility consists of (must be completed prior to Big Ass Fans arrival):

  • Install wall mounted controller to an accessible surface (i.e. column, concrete wall or wood)
  • Install all CAT-5 data communications cable between fan and wall controller
  • Wiring per NEC from power source to fan mounting location
  • Option A: one (1) dedicated circuit breaker per fan in the service panel
  • Option B: for multiple fans on a common branch circuit, one (1) dedicated fused disconnect and/or circuit breaker locally mounted per fan; or no disconnect required per NEC430 part IX, if applicable
  • Install a power connection point that will be comprised of a junction box with a NEMA L-16-20R (480V) or
  • L-15-20R (250V) receptacle Exclusions
  • Clean-up or rework of existing electrical infractions are not included in this scope.
  • Local disconnecting means adjacent to the fan is not included.
  • Relocation of obstacles (lighting, electrical conduits, gas lines, water lines, sprinkler lines etc.) is not included.
  • Fire alarm tie-ins are not included.
  • Permits and inspection fees are not included. Any other requirements beyond the description above are not included.

Level 2 Scope of Work

Big Ass Fans responsibility consists of:

  • Attach mount to I-Beam or standard steel Angle Irons
  • Attach extension tube to upper yoke
  • Secure the safety cable
  • Attach lower yoke to extension tube
  • Attach motor frame to lower yoke
  • Attach winglets to airfoils
  • Attach foil retainers and airfoils to hub
  • Install wall mounted controller to the nearest accessible surface (i.e. column, concrete wall or wood)
  • Connect to customer provided local Power Source (will be housed in conduit until height of ceiling deck is reached)
  • Start-up and operational training

Owner's responsibility consists of (must be completed prior to Big Ass Fans arrival):

  • Wiring per NEC from power source to within 3’ of fan mounting location
  • Install all CAT-5 data communications cable within 100’ of fan location (Big Ass Fans assumes CAT-5 cable
  • Option A: one (1) dedicated circuit breaker per fan in the service panel
  • Option B: for multiple fans on a common branch circuit, one (1) dedicated fused disconnect and/or circuit breaker locally mounted per fan; or no disconnect required per NEC430 part IX, if applicable
  • Install a power connection point that will be comprised of a junction box with a NEMA L-16-20R (480V) or L-15-20R (250V) receptacle

Exclusions

  • Clean-up or rework of existing electrical infractions are not included in this scope.
  • Local disconnecting means adjacent to the fan is not included.
  • Relocation of obstacles (lighting, electrical conduits, gas lines, water lines, sprinkler lines etc.) is not included.
  • Fire alarm tie-ins are not included.
  • Permits and inspection fees are not included. Any other requirements beyond the description above are not included.

Installation Assumptions

Unless otherwise noted, all installations should commence within two weeks of fan shipment.

  • No installation will be scheduled until customer clears credit hold.
  • Assumptions and clarifications: Any of these conditions that are not met will trigger an additional charge to customer.
  • Permits and stamped approvals are not included; if they are required they will pass through expense to customer.
  • Regular working hours 7:00am to 5:00pm Monday-Friday.
  • A ten (10) hour window of work will be provided.
  • 75m conduit run (or less) total.
  • If a lift is provided by customer, the lift will be deemed safe to use, in working condition, fully charged & available for use with no delays.
  • All fans are in one location and under one roof, all installations shall be performed in one trip
  • Circuit breakers are of modern and available type, no bus bars w/o quote from the installer unless provided by the customer.
  • BAF is mounting to 2m or less angle iron or an I beam
  • Conduit to be used for Powerfoil8, Basic 6 and Pivot fans from controller to motor, Shielded cable wiring to be used from MDP to controller
  • Shielded cable to be used on Element, PowerfoilX2.0 and PF8 fans. If customer or locals do not allow AC or MC cable the job will need to be a quoted price.
  • All Lift prices are for 8m narrow scissor lift with no more than $250 each way for freight.
  • Prices for metro installs only – remote locations and regional towns would require additional costs.

Installation Adders

  • If customer’s facility requires a larger lift (up to 14m) increase price by $350 up to 2 fans
  • Structural, mechanical and electrical engineer charges to be incurred by customer.
  • Fabrication and installation of structural engineer design mount.
  • Electrical permits are up to the discretion of the customer responsible for costs.
  • Electrical/Conduit runs greater than 50m will be issued at $3.75 per metre.
  • Data controller runs greater than 50m will be issued at $3.75 per metre (does not include data runs)
  • Data controller runs greater than 50m fully housed in conduit will be issued $13.50 per metre.
  • Rigid pipe is a $22.50 per metre adder to overall cost of job.
  • There is a $450.00 adder for adding light to PFX2.0; the PFX2.0 light will be added to the existing lighting circuit in the area.
  • Fire relay installation: (BAF will not tie into the fire panel)
  • Yellow Jacket Only- Conduit runs over 15m will be issued at an additional $1.00 per metre.