Cooler's control panel is showing an error code. | Big Ass Fans
It's our end of year SWAG sale! Take up to 50%* off select BAF gear and accessories! Use code SWAG21 to save!

Cooler’s control panel is showing an error code.

E1 – Voltage Self-Inspection Error

  • Try a different circuit.
  • Replace the panel.

E2 – Overcurrent Protection

Current draw is too high.

  • Check extension cord size.
  • Check that motor spins freely.
  • Check that airflow is not obstructed.

E3 – Under Voltage Protection

Supply voltage is too low (< 100 V).

  • Try a different circuit.
  • Install a voltage regulator.

E4 – Over Voltage Protection

Supply voltage is too high (> 130 V).

  • Try a different circuit.
  • Install a voltage regulator.

E5 – Overload Protection

Motor is running too hot.

  • Check that airflow is not obstructed.
  • Check extension cord size.

E6 – Overheat Protection

  • Check that airflow is not obstructed.
  • Check for mineral buildup on the motor.
  • Check extension cord size.

E7 – Panel with Motor Communication Error

  • Check for a broken or loose wire.

E8 – Panel Internal Error

  • Replace the panel.

E9 – Motor No Response

  • Check for a broken or loose wire.
  • Replace the motor.

F6 – Panel Communication Error

  • Check for a broken or loose wire.
This applies to these products: Cool-Space® 500

Was This Helpful?

Yes
No

Still need help?